3 Function diagrams
3.23 Terminal Module 31 (TM31)
SINAMICS G130/G150
1250 List Manual (LH2), 04/2014, A5E03263479A
Fig. 3-194 9560 – Digital inputs/outputs, bidirectional (DI/DO 8 ... DI/DO 9)
- 9560 -
Function diagram
87654321
fp_9560_51_eng.vsd
DO: TM31
SINAMICS
27.03.09 V04.07.00
Terminal Module 31 (TM31) - Digital inputs/outputs, bidirectional (DI/DO 8 ... DI/DO 9)
p4095.8 (0)
X541.6 M
p4096.8 (0)
p4048.8 (0)
DI
DO
p4095.9 (0)p4096.9 (0)
p4048.9 (0)
DI
DO
X541.3
DI/DO 9
p4028.9 (0)
DI/DO 8X541.2
p4028.8 (0)
1
0
1
1
0
1
1
0
1
0
0
1
0
1
+24 VX541.1
<1> The connection shown as a dashed line applies
when used as digital output (p4028.x = 1).
<1>
DI
DI
1
1
r4022
r4023.9
r4023.8
r4021.8
r4021.9
r4022.9
r4022.8
p4099[0] (4000.00 μs)
<2> Limits the total output current of the terminals X541.2, X541.3, X541.4 and X541.5 to 0.1 A (p4046 = 0) or 1 A (p4046 = 1).
<3> The total (summed) output current of the 24 V auxiliary power supply on terminals X540.1 to X540.8 and X541.1 is limited to 150 mA.
Incandescent lamps must not be connected to the 24 V auxiliary power supply!
r4047.9
DO
DI/DO 8 9
inverted
DI/DO 8 9
DO
(0)
TM31 S_src DI/DO 9
p4039
(0)
TM31 S_src DI/DO 8
p4038
0
1
0
r4047.8
0
1
0
24 V
5 V
<1>
X540.1
X540.8
+24 V
+
Current
limiting
150 mA
Current
limiting
p4046 (0)
<3> <2>
[9562.4]
[9562.3]
r4023