EasyManua.ls Logo

Siemens SINAMICS G150 - Page 177

Siemens SINAMICS G150
1842 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
177
2 Parameters
2.2 List of parameters
Note: A value of zero is displayed if an encoder is not present.
Re bit 11:
When the property is set, the following parameters can be changed without the actual value in the encoder interface
becoming invalid (state r0481.14 = 1 "parking encoder active"):
p0314, p0315, p0430, p0431, p0441, p0442, p0443, p0444, p0445
Re bit 12:
The extended functions can be configured using p0437.
Re bit 13:
Encoder faults can be acknowledged via Gn_STW.15.
Re bit 14:
Only for internal Siemens use.
Re bit 23:
When the property is set, commutation with zero mark can be de-selected using p0430.23.
Re bit 24:
If the property is set, commutation to the selected zero mark can be carried out.
Description: Sets the Sensor Module configuration.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
r0458[0...2] Sensor Module properties / SM properties
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: 4704
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Encoder data available Yes No -
01 Motor data available Yes No -
02 Temperature sensor connection available Yes No -
03 Connection for PTC for motor with DRIVE-
CLiQ also available
Yes No -
04 Module temperature available Yes No -
05 Absolute encoder p0408/p0421 no power of
2
Yes No -
06 Sensor Module permits parking/unparking Yes No -
07 Hall sensor can be combined with actual
value inversion
Yes No -
08 Evaluation through several temperature
channels possible
Yes No -
09 Encoder fault and its associated information
available
Yes No -
10 Speed diagnostics in the Sensor Module Yes No -
11 Configuring without park state possible Yes No -
12 Extended functions available Yes No -
13 Extended encoder fault handling Yes No -
14 Extended singleturn/multiturn information
available
Yes No -
15 Evaluation function reserve Yes No -
16 Pole position identification Yes No -
17 Burst oversampling Yes No -
18 Continuous oversampling Yes No -
19 Safety position actual value sensing Yes No -
20 Extended speed calculation being used
(only SMC30)
Yes No -
21 Zero mark tolerance Yes No -
22 Rot pos adapt Yes No -
23 Commutation with zero mark can be de-
selected
Yes No -

Table of Contents

Other manuals for Siemens SINAMICS G150

Related product manuals