Name Value Internal
Value
Internal
value,
Type
Default Min. Max. EDS Slot
Index
Output
behaviour
com fault
Off
Last value
Substitute
Last value
5s
Substitute
5s
Last value
10s Sub-
stitute 10s
0
1
2
3
4
5
6
BYTE Off
0x00
0 1 0x0Y16
Substitute
value
0 0 WORD Default
0x0000
0 65536 0x0Y17
1
) With CS31 and addresses smaller than 70 and FBP, the value is increased by 1
2
) Not with FBP
3
) Value is hexadecimal: HighByte is slot (xx: 1...10), LowByte is index (1...n)
Table 94: Operating modes for counters 0 and 1, configuration table
Internal value Operating modes of counter
0 No counter / No PWM (default value)
1 1-1 UpDown counter (A)
2 2-1 UpDown with release input
3 3-2 UpDown counters (A, B)
4 4-2 UpDown (A, B on falling edges)
5 5-1 UpDown dynamic set (B) / rising edge
6 6-1 UpDown dynamic set (B) / falling edge
7 Not used
8 8-1 UpDown with release (B), 0 cross detection
9 - 19 Not used
20 11-1 Incremental encoder
21 12-2 Incremental encoder X2
22 13-1 Incremental encoder X4
30 14-1 SSI, absolute encoder
40 15-1 Time frequency meter
2019/04/17 3ADR010121, 13, en_US 665