5-26
Cisco ONS 15454 Procedure Guide, R5.0
December 2004
Chapter 5 Turn Up Network
NTP-A217 Provision an Integrated Path Protection Dual-Ring Interconnect
NTP-A217 Provision an Integrated Path Protection Dual-Ring
Interconnect
Step 1 Complete the “DLP-A60 Log into CTC” task on page 17-66 at a node in the path protection DRI
network. If you are already logged in, continue with Step 2.
Step 2 Complete the following steps if you have not provisioned the path protection configurations that you will
interconnect in a path protection DRI. If the path protection configurations are created, continue with
Step 3.
a. Complete the “NTP-A44 Provision Path Protection Nodes” procedure on page 5-20 to provision the
path protection configurations.
b. Complete the “NTP-A177 Path Protection Acceptance Test” procedure on page 5-22 to test the path
protection configurations.
Note All path protection configurations that will be interconnected must have the same OC-N rate.
Step 3 Verify that the path protection DRI interconnect nodes have OC-N cards installed and have fiber
connections to the other interconnect node:
The OC-N cards that will connect the path protection configurations must be installed at the
interconnect nodes. The OC-N cards in the path protection nodes and the interconnect nodes must
be the same type.
The interconnect nodes must have the correct fiber connections. An example is shown in Figure 5-8.
This example shows a path protection DRI with two rings.
Purpose This procedure provisions path protection configurations in an integrated
DRI topology. In the integrated DRI, the path protection OC-N trunk cards
for both path protection configurations are installed on the same shelf.
Tools/Equipment None
Prerequisite Procedures NTP-A35 Verify Node Turn-Up, page 5-2
Required/As Needed As needed
Onsite/Remote Onsite
Security Level Provisioning and higher

Table of Contents

Other manuals for Cisco ONS 15454 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ONS 15454 Series and is the answer not in the manual?

Cisco ONS 15454 Series Specifications

General IconGeneral
Supported InterfacesEthernet
ManagementCisco Transport Controller (CTC), TL1, SNMP
Power Supply-48 VDC or AC (depending on power supply module)
Operating Temperature0 to 50°C (32 to 122°F) - varies by module
Storage Temperature-40°C to 70°C (-40 to 158°F)
Relative Humidity5 to 95%, noncondensing
Supported ProtocolsSONET/SDH, Ethernet, OTN
Platform TypeMulti-service transport platform

Related product manuals