17-77
Cisco ONS 15454 Procedure Guide, R5.0
March 2005
Chapter 17 DLPs A1 to A99
DLP-A70 Set Up Internal Timing
Step 6 If BITS In State is set to OOS, continue with Step 7. If the BITS In State is set to IS, complete the
following information:
Coding—Choose the coding used by your BITS reference, either B8ZS (binary 8-zero substitution)
or AMI (alternate mark inversion).
Framing—Choose the framing used by your BITS reference, either ESF (Extended Super Frame) or
SF (D4) (Super Frame).
Sync Messaging—Check this check box to enable SSM. SSM is not available if Framing is set to
Super Frame.
Admin SSM—If the Sync Messaging check box is not checked, you can choose the SSM
Generation 2 type from the drop-down list.
Step 7 In the BITS Out area, complete the following information, as needed:
Facility Type—choose the BITS Out signal type, either DS1 or 64 Khz.
BITS Out State—If equipment is connected to the node’s BITS output pins on the backplane and
you want to time the equipment from a node reference, set the BITS Out State for BITS-1 and/or
BITS-2 to IS, depending on which BITS Out pins are used for the external equipment. If equipment
is not attached to the BITS output pins, set the BITS Out State to OOS.
Step 8 If the BITS Out State is set to OOS, continue with Step 9. If BITS Out State is set to IS, complete the
following information:
Coding—Choose the coding used by your BITS reference, either B8ZS or AMI.
Framing—Choose the framing used by your BITS reference, either ESF or SF (D4).
AIS Threshold—If SSM is disabled or Super Frame is used, choose the quality level where a node
sends an AIS from the BITS 1 Out and BITS 2 Out backplane pins. An AIS alarm is raised when the
optical source for the BITS reference falls to or below the SSM quality level defined in this field.
LBO—If you are timing an external device connected to the BITS Out pins, choose the distance
between the device and the ONS 15327. Options are: 0-133 ft. (default), 124-266 ft., 267-399 ft.,
400-533 ft., and 534-655 ft. Line build out (LBO) relates to the BITS cable length.
Step 9 Click Apply.
Note Refer to the Cisco ONS 15454 Troubleshooting Guide for timing-related alarms.
Step 10 Return to your originating procedure (NTP).
DLP-A70 Set Up Internal Timing
Purpose This task sets up internal timing (Stratum 3) for an ONS 15454.
Tools/Equipment None
Prerequisite Procedures DLP-A60 Log into CTC, page 17-66
Required/As Needed As needed (use only if a BITS source is not available)
Onsite/Remote Onsite or remote
Security Level Provisioning or higher

Table of Contents

Other manuals for Cisco ONS 15454 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ONS 15454 Series and is the answer not in the manual?

Cisco ONS 15454 Series Specifications

General IconGeneral
Supported InterfacesEthernet
ManagementCisco Transport Controller (CTC), TL1, SNMP
Power Supply-48 VDC or AC (depending on power supply module)
Operating Temperature0 to 50°C (32 to 122°F) - varies by module
Storage Temperature-40°C to 70°C (-40 to 158°F)
Relative Humidity5 to 95%, noncondensing
Supported ProtocolsSONET/SDH, Ethernet, OTN
Platform TypeMulti-service transport platform

Related product manuals