19-17
Cisco ONS 15454 Procedure Guide, R5.0
September 2005
Chapter 19 DLPs A200 to A299
DLP-A225 Enable Alarm Filtering
DLP-A225 Enable Alarm Filtering
Step 1 At the node, network, or card view, click the Alarms tab.
Step 2 Click the Filter tool at the lower-left side of the bottom toolbar.
Alarm filtering is enabled if the tool is selected and disabled if the tool is raised (not selected).
Alarm filtering will be enabled in the card, node, and network views of the Alarms tab at the node and
for all other nodes in the network. If, for example, the Alarm Filter tool is enabled in the Alarms tab of
the node view at one node, the Alarms tab in the network view and card view of that node will also show
the tool enabled. All other nodes in the network will also have the tool enabled.
If you filter an alarm in card view, the alarm will still be displayed in node view. In this view, the card
will display the color of the highest-level alarm. The alarm is also shown for the node in the network
view.
Step 3 If you want alarm filtering enabled when you view conditions, repeat Steps 1 and 2 using the Conditions
window.
Step 4 If you want alarm filtering enabled when you view alarm history, repeat Steps 1 and 2 using the History
window.
Step 5 Return to your originating procedure (NTP).
DLP-A227 Disable Alarm Filtering
Step 1 At the node, network, or card view, click the Alarms tab.
Step 2 Click the Filter tool at the lower-right side of the bottom toolbar.
Alarm filtering is enabled if the tool is indented and disabled if the tool is raised (not selected).
Purpose This task enables alarm filtering for alarms, conditions, or event history in
all network nodes.
Tools/Equipment None
Prerequisite Procedures DLP-A60 Log into CTC, page 17-66
Required/As Needed As needed
Onsite/Remote
Onsite or remote
Security Level
Retrieve
Purpose This task turns off specialized alarm filtering in all network nodes so that
all severities are reported in CTC.
Tools/Equipment None
Prerequisite Procedures DLP-A225 Enable Alarm Filtering, page 19-17
DLP-A60 Log into CTC, page 17-66
Required/As Needed As needed
Onsite/Remote
Onsite or remote
Security Level
Retrieve

Table of Contents

Other manuals for Cisco ONS 15454 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ONS 15454 Series and is the answer not in the manual?

Cisco ONS 15454 Series Specifications

General IconGeneral
Supported InterfacesEthernet
ManagementCisco Transport Controller (CTC), TL1, SNMP
Power Supply-48 VDC or AC (depending on power supply module)
Operating Temperature0 to 50°C (32 to 122°F) - varies by module
Storage Temperature-40°C to 70°C (-40 to 158°F)
Relative Humidity5 to 95%, noncondensing
Supported ProtocolsSONET/SDH, Ethernet, OTN
Platform TypeMulti-service transport platform

Related product manuals