17-63
Cisco ONS 15454 Procedure Guide, R5.0
March 2005
Chapter 17 DLPs A1 to A99
DLP-A53 Set Up a Solaris Workstation for a Craft Connection to an ONS 15454
i. In the Local Area Connection Properties dialog box, click OK.
j. In the Local Area Connection Status dialog box, click Close.
Step 6 If you have Windows XP installed on your PC, complete the following steps to change its TCP/IP
configuration:
a. From the Windows Start menu, choose Control Panel > Network Connections.
Note If the Network Connections menu item is not available, click Switch to Classic View.
b. From the Network Connections dialog box, click the Local Area Connection icon.
c. From the Local Area Connection Properties dialog box, choose Internet Protocol (TCP/IP), then
click Properties.
d. In the IP Address field, enter any legitimate IP address other than the node IP address.
e. In the Subnet Mask field, type the same subnet mask as the ONS 15454. The default is
255.255.255.0 (24 bit).
f. Type the IP address entered in Step d in the Gateway Address field.
g. Click OK.
h. In the Local Area Connection Properties dialog box, click OK.
i. In the Local Area Connection Status dialog box, click Close.
Step 7 Return to your originating procedure (NTP).
DLP-A53 Set Up a Solaris Workstation for a Craft Connection to an ONS 15454
Step 1 Log into the workstation as the root user.
Step 2 Check to see if the interface is plumbed by typing:
# ifconfig device
For example:
# ifconfig hme1
If the interface is plumbed, a message similar to the following appears:
hme1:flags=1000842<BROADCAST,RUNNING,MULTICAST,IPv4>mtu 1500 index 2 inet 0.0.0.0 netmask 0
If a message similar to this one appears, go to Step 4.
Purpose This task sets up a Solaris workstation for a craft connection to the
ONS 15454.
Tools/Equipment None
Prerequisite Procedures NTP-A260 Set Up Computer for CTC, page 3-1
Required/As Needed As needed
Onsite/Remote Onsite
Security Level None

Table of Contents

Other manuals for Cisco ONS 15454 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ONS 15454 Series and is the answer not in the manual?

Cisco ONS 15454 Series Specifications

General IconGeneral
Supported InterfacesEthernet
ManagementCisco Transport Controller (CTC), TL1, SNMP
Power Supply-48 VDC or AC (depending on power supply module)
Operating Temperature0 to 50°C (32 to 122°F) - varies by module
Storage Temperature-40°C to 70°C (-40 to 158°F)
Relative Humidity5 to 95%, noncondensing
Supported ProtocolsSONET/SDH, Ethernet, OTN
Platform TypeMulti-service transport platform

Related product manuals