Cisco ONS 15454 Series - DLP- A442 Verify Pass-Through Circuits

Cisco ONS 15454 Series
850 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21-23
Cisco ONS 15454 Procedure Guide, R5.0
March 2005
Chapter 21 DLPs A400 to A499
DLP-A442 Verify Pass-Through Circuits
DLP-A442 Verify Pass-Through Circuits
Step 1 In the CTC Circuits window, choose a circuit that passes through the node that will be removed and click
Edit.
Step 2 In the Edit Circuits window, check Show Detailed Map.
Step 3 Verify that the STS and VT mapping on the node’s east and west ports are the same. For example, if the
circuit mapping on the west port is s5/p1/S1 (Slot 5, Port 1, STS 1), verify that the mapping is STS 1 on
the east port. If the circuit displays different STSs and/or VTs on the east and west ports, record the name
of the circuit. Figure 21-2 shows a circuit passing through a node (doc-124) on the same STS (STS 2).
Figure 21-2 Verifying Pass-Through STSs
Step 4 Repeat Steps 1 to 3 for each circuit in the Circuits tab.
Step 5 Delete and recreate each circuit recorded in Step 3. To delete the circuit, see the “DLP-A333 Delete
Circuits” task on page 20-21. To create the circuit, see Chapter 6, “Create Circuits and VT Tunnels.”
Step 6 Return to your originating procedure (NTP).
Purpose This task verifies that circuits passing through a node enter and exit the
node on the same STS and/or VT.
Tools/Equipment None
Prerequisite Procedures DLP-A60 Log into CTC, page 17-66
Required/As Needed As needed
Onsite/Remote Onsite or remote