18-4
Cisco ONS 15454 Procedure Guide, R5.0
March 2007
Chapter 18 DLPs A100 to A199
DLP-A114 View Conditions
DLP-A114 View Conditions
Step 1 From the card, node, or network view, click the Conditions tab.
Step 2 Click Retrieve (Figure 18-2).
The Retrieve button requests the current set of fault conditions from the node, card, or network. The
window is not updated when events change on the node. You must click Retrieve to see any changes.
Figure 18-2 Node View Conditions Window
Conditions include all fault conditions raised on the node, whether or not they are reported.
Note Alarms can be unreported when they are filtered out of the display. See the “DLP-A225 Enable
Alarm Filtering” task on page 19-17 for information.
Events that are reported as Major (MJ), Minor (MN), or Critical (CR) severities are alarms. Events that
are reported as Not Alarmed (NA) are conditions. Conditions that are not reported at all are marked NR
in the Conditions window severity column. Conditions that have a default severity of CR, MJ, MN, or
NA but are not reported due to exclusion or suppression are shown as NR in the Conditions window.
Purpose This task is used to view conditions (events with a Not Reported [NR]
severity) at the card, node, or network level. Conditions give you a clear
record of changes or events that do not result in alarms.
Tools/Equipment None
Prerequisite Procedures DLP-A60 Log into CTC, page 17-66
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Retrieve or higher