6-85
Cisco ONS 15454 Procedure Guide, R5.0
August 2005
Chapter 6 Create Circuits and VT Tunnels
NTP-A194 Create Overhead Circuits
Note An Encapsulation Mismatch Path alarm appears when a point-to-point circuit is created between
two Ethernet card ports with incompatible Encapsulation payload types.
Step 5 Click Apply.
Step 6 Refresh the POS statistics:
a. Click the Performance > POS Ports > Statistics tabs.
b. Click Refresh.
Stop. You have completed this procedure.
NTP-A194 Create Overhead Circuits
Step 1 Complete the “DLP-A60 Log into CTC” task on page 17-66 at the node where you will create the
overhead circuit. If you are already logged in, continue with Step 2.
Step 2 From the View menu, choose Go to Network View.
Step 3 As needed, complete the “DLP-A313 Create a DCC Tunnel” task on page 20-7.
Step 4 As needed, complete the “DLP-A341 Create an IP-Encapsulated Tunnel” task on page 20-32.
Step 5 As needed, complete the “DLP-A83 Provision Orderwire” task on page 17-84.
Step 6 As needed, complete the “DLP-A212 Create a User Data Channel Circuit” task on page 19-8.
Stop. You have completed this procedure.
Purpose This procedure creates overhead circuits on an ONS 15454 network.
Overhead circuits include DCC tunnels, IP-encapsulated tunnels, the
Alarm Interface Controller (AIC) and Alarm Interface
Controller-International (AIC-I) card orderwire, and the AIC-I card user
data channel (UDC).
Tools/Equipment None
Prerequisite Procedures NTP-A127 Verify Network Turn Up, page 6-4
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Provisioning or higher

Table of Contents

Other manuals for Cisco ONS 15454 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ONS 15454 Series and is the answer not in the manual?

Cisco ONS 15454 Series Specifications

General IconGeneral
Supported InterfacesEthernet
ManagementCisco Transport Controller (CTC), TL1, SNMP
Power Supply-48 VDC or AC (depending on power supply module)
Operating Temperature0 to 50°C (32 to 122°F) - varies by module
Storage Temperature-40°C to 70°C (-40 to 158°F)
Relative Humidity5 to 95%, noncondensing
Supported ProtocolsSONET/SDH, Ethernet, OTN
Platform TypeMulti-service transport platform