Chapter 7 Manage Alarms
NTP-A69 View Alarm-Affected Circuits
Step 5 To remove the transient messages from the History window, click Delete Cleared Alarms. Transient
messages are single messages, not raise-and-clear pairs (that is, they do not have companion messages
stating they are cleared).
Stop. You have completed this procedure.
NTP-A69 View Alarm-Affected Circuits
Step 1 Complete the “DLP-A60 Log into CTC” task on page 17-66. If you are already logged in, continue with
Step 2.
Step 2 In the network, node, or card view, click the Alarms tab or Conditions tab and then right-click anywhere
in the row of an active alarm or condition.
Note The node view is the default, but you can also navigate to the Alarms tab in the network view or
card view to perform Step 2.
The Select Affected Circuit option appears on the shortcut menu (Figure 7-1).
Purpose Use this procedure to view all circuits, if any, that are affected by an alarm
or condition.
Tools/Equipment None
Prerequisite Procedures NTP-A196 View Alarms, History, Events, and Conditions, page 7-2
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Retrieve or higher