15-36
Cisco ONS 15454 Procedure Guide, R5.0
December 2004
Chapter 15 Maintain the Node
NTP-A165 Import Network Element Defaults
Step 3 Under Defaults Selector, choose a card type (if editing card-level defaults), CTC (if editing CTC
defaults), or NODE (if editing node-level defaults). Clicking on the node name (at the top of the Defaults
Selector column) lists all available NE defaults in the Default Name column. To selectively display just
the defaults for a given card type, for node-level, or for CTC-level, you can drill down the Defaults
Selector menu structure.
Step 4 Locate a default you want to change under Default Name.
Step 5 Click in the Default Value column for the default property you are changing and either choose a value
from the drop-down menu (when available), or type in the desired new value.
Note If you click Reset before you click Apply, all values will return to their original settings.
Step 6 Click Apply (click in the Default Name column to activate the Apply button if it is unavailable). You
can modify multiple default values before applying the changes.
A pencil icon will appear next to any default value that will be changed as a result of editing the defaults
file.
Step 7 If you are modifying node-level defaults, a dialog box appears telling you that applying defaults for node
level attributes overrides current provisioning and asks if you want to continue. Click Yes .
If you are modifying the IIOP Listener Port setting, a dialog box appears warning you that the node will
reboot and asks if you want to continue. Click Ye s.
Note Changes to node settings take effect when you click Apply. Changes made to card settings using
the Defaults Editor do not change the settings for cards that are already installed or slots that are
pre-provisioned for cards. To change settings for installed cards or pre-provisioned slots, see
Chapter 11, “Change Card Settings.”
Note Changes to the IIOP Listener Port setting cause the TCC2/TCC2P card to reboot.
Stop. You have completed this procedure.
NTP-A165 Import Network Element Defaults
Purpose This procedure imports the NE defaults using the NE Defaults Editor. The
defaults can either be imported from the CTC software CD (factory
defaults) or from a customized file exported and saved from a node.
Tools/Equipment None
Prerequisite Procedures None
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Superuser

Table of Contents

Other manuals for Cisco ONS 15454 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ONS 15454 Series and is the answer not in the manual?

Cisco ONS 15454 Series Specifications

General IconGeneral
Supported InterfacesEthernet
ManagementCisco Transport Controller (CTC), TL1, SNMP
Power Supply-48 VDC or AC (depending on power supply module)
Operating Temperature0 to 50°C (32 to 122°F) - varies by module
Storage Temperature-40°C to 70°C (-40 to 158°F)
Relative Humidity5 to 95%, noncondensing
Supported ProtocolsSONET/SDH, Ethernet, OTN
Platform TypeMulti-service transport platform

Related product manuals