18-43
Cisco ONS 15454 Procedure Guide, R5.0
March 2007
Chapter 18 DLPs A100 to A199
DLP-A168 Change Line and Threshold Settings for the DS3XM-6 Card
Table 18-16 lists the line threshold options for DS3XM-6 cards.
Table 18-17 describes the values on the Provisioning > Elect Path Thresholds tabs for the DS3XM-6
cards.
Service State Identifies the autonomously
generated state that gives the
overall condition of the port.
Service states appear in the
format: Primary State-Primary
State Qualifier, Secondary State.
• IS-NR—(In-Service and Normal) The port is
fully operational and performing as provisioned.
• OOS-AU,AINS—(Out-Of-Service and
Autonomous, Automatic In-Service) The port is
out-of-service, but traffic is carried. Alarm
reporting is suppressed. The ONS node monitors
the ports for an error-free signal. After an
error-free signal is detected, the port stays in
OOS-AU,AINS state for the duration of the soak
period. After the soak period ends, the port
service state changes to IS-NR.
• OOS-MA,DSBLD—(Out-of-Service and
Management, Disabled) The port is
out-of-service and unable to carry traffic.
• OOS-MA,MT—(Out-of-Service and
Management, Maintenance) The port is
out-of-service for maintenance. Alarm reporting
is suppressed, but traffic is carried and
loopbacks are allowed.
AINS Soak Sets the automatic in-service
soak period.
• Duration of valid input signal, in hh.mm format,
after which the card becomes in service (IS)
automatically
• 0 to 48 hours, 15-minute increments
Table 18-15 Line Options for the DS3XM-6 Parameters (continued)
Parameter Description Options
Table 18-16 Line Threshold Options for the DS3XM-6 Card
Parameter Description Options
Port (Display only.) Port number 1 to 6
CV Coding violations Numeric. Can be set for 15-minute or
one-day intervals. Select the bullet and
click Show Thresholds.
ES Errored seconds Numeric. Can be set for 15-minute or
one-day intervals. Select the bullet and
click Show Thresholds.
SES Severely errored seconds Numeric. Can be set for 15-minute or
one-day intervals. Select the bullet and
click Show Thresholds.
LOSS Loss of signal seconds Numeric. Can be set for 15-minute or
one-day intervals. Select the bullet and
click Show Thresholds.