18-3
Cisco ONS 15454 Procedure Guide, R5.0
March 2007
Chapter 18 DLPs A100 to A199
DLP-A112 Display Alarms and Conditions Using Time Zone
DLP-A112 Display Alarms and Conditions Using Time Zone
Step 1 From the Edit menu, choose Preferences.
The CTC Preferences dialog box appears (Figure 18-1 on page 18-2).
Step 2 Check the Display Events Using Each Node’s Timezone check box. The Apply button is enabled.
Step 3 Click Apply and OK.
Step 4 Return to your originating procedure (NTP).
DLP-A113 Synchronize Alarms
Step 1 At the card, node, or network view, click the Alarms tab.
Step 2 Click Synchronize.
This button causes CTC to retrieve a current alarm summary for the card, node, or network. This step is
optional because CTC updates the Alarms window automatically as raise/clear messages arrive from the
node.
Note Alarms that have been raised during the session will have a check mark in the Alarms window
New column. When you click Synchronize, the check mark disappears.
Step 3 Return to your originating procedure (NTP).
Purpose This task changes the time stamp for events to the time zone of the ONS
node reporting the alarm. By default, the events time stamp is set to the
time zone for the CTC workstation.
Tools/Equipment None
Prerequisite Procedures DLP-A60 Log into CTC, page 17-66
Required/As Needed As needed
Onsite/Remote
Onsite or remote
Security Level
Provisioning or higher
Purpose This task is used to view ONS 15454 events at the card, node, or network
level and to refresh the alarm listing so that you can check for new and
cleared alarms and conditions.
Tools/Equipment None
Prerequisite Procedures DLP-A60 Log into CTC, page 17-66
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Retrieve or higher