17-56
Cisco ONS 15454 Procedure Guide, R5.0
March 2005
Chapter 17 DLPs A1 to A99
DLP-A50 Set Up a Windows PC for Craft Connection to an ONS 15454 on the Same Subnet Using Static IP Addresses
DLP-A50 Set Up a Windows PC for Craft Connection to an ONS 15454 on the
Same Subnet Using Static IP Addresses
Step 1 Verify the operating system that is installed on your computer:
a. From the Windows Start menu, choose Settings > Control Panel.
b. In the Control Panel window, double-click the System icon.
c. On the General tab of the System Settings window, verify that the Windows operating system is one
of the following: Windows 98, Windows NT 4.0, Windows 2000, or Windows XP.
Step 2 According to the Windows operating system installed on your computer, perform one of the following
steps:
For Windows 98, complete Step 3.
For Windows NT 4.0, complete Step 4.
For Windows 2000, complete Step 5.
For Windows XP, complete Step 6.
Step 3 If you have Windows 98 installed on your PC, complete the following steps to change its TCP/IP
configuration:
a. From the Windows Start menu, choose Settings > Control Panel.
b. In the Control Panel dialog box, click the Network icon.
c. In the Network dialog box, choose TCP/IP for your network interface card (NIC), then click
Properties.
d. In the TCP/IP Properties dialog box, click the DNS Configuration tab and choose Disable DNS.
e. Click the WINS Configuration tab and choose Disable WINS Resolution.
f. Click the IP Address tab.
g. In the IP Address window, click Specify an IP address.
Purpose This task sets up your computer for a local craft connection to the
ONS 15454 when:
You will access nodes running software releases earlier than Software
Release 3.3.
You will connect to one ONS 15454; if you will connect to multiple
ONS 15454s, you might need to reconfigure your computer’s IP
settings each time you connect to an ONS 15454.
You need to use non-ONS 15454 applications such as ping and tracert
(trace route).
Tools/Equipment None
Prerequisite Procedures NTP-A260 Set Up Computer for CTC, page 3-1
Required/As Needed As needed
Onsite/Remote Onsite
Security Level None

Table of Contents

Other manuals for Cisco ONS 15454 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ONS 15454 Series and is the answer not in the manual?

Cisco ONS 15454 Series Specifications

General IconGeneral
Supported InterfacesEthernet
ManagementCisco Transport Controller (CTC), TL1, SNMP
Power Supply-48 VDC or AC (depending on power supply module)
Operating Temperature0 to 50°C (32 to 122°F) - varies by module
Storage Temperature-40°C to 70°C (-40 to 158°F)
Relative Humidity5 to 95%, noncondensing
Supported ProtocolsSONET/SDH, Ethernet, OTN
Platform TypeMulti-service transport platform

Related product manuals