6-77
Cisco ONS 15454 Procedure Guide, R5.0
August 2005
Chapter 6 Create Circuits and VT Tunnels
NTP-A148 Create a Manual Cross-Connect for a G-Series or E-Series Card in Port-Mapped Mode
State—The circuit is in service (default).
Apply to drop ports—Uncheck this box.
Protected Drops—Leave the default unchanged (unchecked).
Step 9 If the circuit will be routed on a path protection, complete the “DLP-A218 Provision Path Protection
Selectors” task on page 19-12.
Step 10 Click Next.
Step 11 Provision the circuit source:
a. From the Node drop-down list, choose the circuit source node.
b. From the Slot drop-down list, choose the Ethernet card that will be the cross-connect source.
c. From the Port drop-down list, choose the cross-connect source port.
Step 12 Click Next.
Step 13 Provision the circuit destination:
a. From the Node drop-down list, choose the cross-connect source node selected in Step 11. (For
Ethernet cross-connects, the source and destination nodes are the same.)
b. From the Slot drop-down list, choose the OC-N card that connects to the non-ONS equipment.
c. Depending on the OC-N card, choose the port and STS from the Port and STS drop-down lists.
Step 14 Click Next.
Step 15 In the left pane of the Circuit Routing Preferences panel, confirm that the following information is
correct:
Circuit name
Circuit type
Circuit size
ONS nodes
Step 16 If the information is not correct, click the Back button and repeat Steps 5 through 15 with the correct
information. If the information is correct, check Route Automatically.
Step 17 Click Finish.
Step 18 Complete the “NTP-A149 Test G-Series Circuits” procedure on page 6-81.
Stop. You have completed this procedure.

Table of Contents

Other manuals for Cisco ONS 15454 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ONS 15454 Series and is the answer not in the manual?

Cisco ONS 15454 Series Specifications

General IconGeneral
Supported InterfacesEthernet
ManagementCisco Transport Controller (CTC), TL1, SNMP
Power Supply-48 VDC or AC (depending on power supply module)
Operating Temperature0 to 50°C (32 to 122°F) - varies by module
Storage Temperature-40°C to 70°C (-40 to 158°F)
Relative Humidity5 to 95%, noncondensing
Supported ProtocolsSONET/SDH, Ethernet, OTN
Platform TypeMulti-service transport platform