6-77
Cisco ONS 15454 Procedure Guide, R5.0
August 2005
Chapter 6 Create Circuits and VT Tunnels
NTP-A148 Create a Manual Cross-Connect for a G-Series or E-Series Card in Port-Mapped Mode
• State—The circuit is in service (default).
• Apply to drop ports—Uncheck this box.
• Protected Drops—Leave the default unchanged (unchecked).
Step 9 If the circuit will be routed on a path protection, complete the “DLP-A218 Provision Path Protection
Selectors” task on page 19-12.
Step 10 Click Next.
Step 11 Provision the circuit source:
a. From the Node drop-down list, choose the circuit source node.
b. From the Slot drop-down list, choose the Ethernet card that will be the cross-connect source.
c. From the Port drop-down list, choose the cross-connect source port.
Step 12 Click Next.
Step 13 Provision the circuit destination:
a. From the Node drop-down list, choose the cross-connect source node selected in Step 11. (For
Ethernet cross-connects, the source and destination nodes are the same.)
b. From the Slot drop-down list, choose the OC-N card that connects to the non-ONS equipment.
c. Depending on the OC-N card, choose the port and STS from the Port and STS drop-down lists.
Step 14 Click Next.
Step 15 In the left pane of the Circuit Routing Preferences panel, confirm that the following information is
correct:
• Circuit name
• Circuit type
• Circuit size
• ONS nodes
Step 16 If the information is not correct, click the Back button and repeat Steps 5 through 15 with the correct
information. If the information is correct, check Route Automatically.
Step 17 Click Finish.
Step 18 Complete the “NTP-A149 Test G-Series Circuits” procedure on page 6-81.
Stop. You have completed this procedure.