22-24
Cisco ONS 15454 Procedure Guide, R5.0
October 2005
Chapter 22 DLPs A500 to A599
DLP-A526 Change Line and Threshold Settings for the DS3i-N-12 Cards
Table 22-3 describes the values on the Provisioning > Elect Path Thresholds tabs for the DS3i-N-12
cards.
Table 22-4 describes the values on the Provisioning > SONET Thresholds tabs for the DS3i-N-12 cards.
ES Errored seconds Numeric. Can be set for 15-minute or one-day intervals.
Select the bullet and click the Show Thresholds button.
SES Severely errored seconds Numeric. Can be set for 15-minute or one-day intervals.
Select the bullet and click the Show Thresholds button.
LOSS Loss of signal seconds; number
of one-second intervals
containing one or more LOS
defects
Numeric. Can be set for 15-minute or one-day intervals.
Select the bullet and click the Show Thresholds button.
Table 22-2 Line Threshold Options for the DS3i-N-12 Cards (continued)
Parameter Description Options
Table 22-3 Electrical Path Options for the DS3i-N-12 Cards
Parameter Description Options
Port (Display only.) Port number 1 to 12
CVP Coding violations Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click the
Show Thresholds button (DS3 Pbit: Near End only;
DS3 CPbit: Near and Far End).
ESP Errored seconds Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click
Show Thresholds (DS3 Pbit: Near End only; DS3
CPbit: Near and Far End).
SESP Severely errored seconds Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click
Show Thresholds (DS3 Pbit: Near End only; DS3
CPbit: Near and Far End).
SASP Severely errored frame/alarm
indication signal–path
Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click
Show Thresholds (DS3 Pbit: Near End only; DS3
CPbit: Near and Far End).
UASP Unavailable seconds–path Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click
Show Thresholds (DS3 Pbit: Near End only; DS3
CPbit: Near and Far End).
AISSP Alarm indication signal
seconds–path
Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click
Show Thresholds (DS3 Pbit: Near End only; DS3
CPbit: Near and Far End).