16-2
Cisco ONS 15454 Procedure Guide, R5.0
December 2004
Chapter 16 Power Down the Node
NTP-A114 Power Down the Node
Step 3 Verify that the node is not connected to a network.
a. If the node is part of a working network, log out of the node and complete the “NTP-A313 Remove
an In-Service Node from a Linear ADM” procedure on page 14-17, the “NTP-A240 Remove a
BLSR Node” procedure on page 14-6, or the “NTP-A294 Remove a Path Protection Node”
procedure on page 14-11. If the node is part of a Software R5.0 Multiservice Transport Platform
(MSTP) configuration, consult your network administrator. Continue with Step 4.
b. If the node is not connected to a working network and the current configurations are no longer
required, proceed to Step 4.
Note Current configurations will be saved if Steps 4 to 13 are skipped.
Step 4 In node view, click the Circuits tab and verify that no circuits are displayed, then proceed to Step 5. If
circuits are displayed, delete all the circuits that originate or terminate in the node, as follows:
Note When deleting circuits from a node, make sure that the node is not connected to any network.
a. Click the circuits that need to be deleted and click Delete.
b. Click Yes.
Repeat until no circuits are displayed.
Step 5 In node view, click the Provisioning > Protection tabs and delete all protection groups:
a. Click the protection group that needs to be deleted and click Delete.
b. Click Yes.
Repeat until no protection groups are displayed.
Step 6 In node view, click the Provisioning > Comm Channels tabs and delete all communications channel
terminations:
a. Click the section data communications channel (SDCC), line data communications channel
(LDCC), generic communications channel (GCC), or OSC termination that needs to be deleted and
click Delete.
b. Click Yes.
Repeat until no SDCC, LDCC, GCC, or OSC terminations are present.
Note Before deleting the OSC termination, make sure the Ring ID is deleted. Click the Provisioning
> Comm Channels > OSC tabs. Select the Ring ID and click Delete.
Step 7 For each installed OC-N or DS-N card, place all ports in Out-of-Service and Management, Disabled
(OOS-MA,DSBLD) service status:
a. In card view, click the Provisioning > Line tabs.
b. Click under the Status column for each port and make sure that OOS,DSBLD is selected.
Note Refer to ONS 15454 DWDM Installation and Operations Manual for information regarding
DWDM cards.
Step 8 Remove all fiber connections to the cards.