AKD User Guide | VL Parameters
General Information
Type R/W Parameter
Description
Sets the ratio of the estimated load moment of inertia relative to the motor
moment of inertia; active in opmodes 1 (velocity) and 2 (position) only.
Units NA
Range 0 to 100.0
Default Value 0
Data Type Float
See Also IL.KACCFF, IL.FF
Start Version M_01-00-00-000
Fieldbus Index/Subindex Object Start Version
Modbus 880 M_01-03-00-000
Description
This parameter is used in the internal calculation of the current loop acceleration feed forward gain value.
Related Topics
11.4 Velocity Loop
644 Kollmorgen | December 2010

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing

Related product manuals