AKD User Guide |
Object 60FFh: target velocity (DS402)
The speed setpoint (target velocity) represents the setpoint for the ramp generator.
Index 60FFh
Name target velocity, VL.CMDU
Object code VAR
Data type INTEGER32
Mode pv
Access R/W
PDO mapping possible
Unit increments
Value range (-2
31
) to (2
31
-1)
Default value
EEPROM no
99 Kollmorgen | December 2010

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing