3 Function diagrams
3.5 PROFIdrive
SINAMICS G130/G150
1092 List Manual (LH2), 04/2014, A5E03263479A
Fig. 3-54 2498 – E_DIGITAL interconnection
- 2498 -
Function diagram
87654321
fp_2498_54_eng.vsd
DO: CU_G, CU_S
S120/S150/G130/G150
20.09.11 V04.07.00
PROFIdrive - E_DIGITAL interconnection
Signal targets for E_DIGITAL
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
--
Inverted
[Function diagram]
signal target
-
-
-
-
-
-
-
E_DIGITAL.1
E_DIGITAL.2
E_DIGITAL.3
E_DIGITAL.4
E_DIGITAL.5
E_DIGITAL.6
E_DIGITAL.8
E_DIGITAL.9
E_DIGITAL.11
E_DIGITAL.12
E_DIGITAL.13
E_DIGITAL.14
E_DIGITAL.15
E_DIGITAL.7
E_DIGITAL.10
E_DIGITAL.0
Signal
<3> Pre-assignment, can be freely changed.
Digital input 12 (DI/DO 12)
Digital input 15 (DI/DO 15)
Digital input 2 (DI 2)
Digital input 4 (DI 4)
Digital input 14 (DI/DO 14)
Digital input 13 (DI/DO 13)
Digital input 11 (DI/DO 11)
Digital input 10 (DI/DO 10)
Digital input 9 (DI/DO 9)
Digital input 1 (DI 1)
Digital input 3 (DI 3)
Digital input 5 (DI 5)
Digital input 6 (DI 6)
Digital input 7 (DI 7)
Digital input 8 (DI/DO 8)
Meaning
Digital input 0 (DI 0)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
[Function diagram]
Internal status word
-
<3>
Interconnection
parameters
p2081[0] = r0722.8
p2081[3] = r0722.11
p2081[5] = r0722.13
p2081[6] = r0722.14
p2081[7] = r0722.15
p2081[8] = r0722.0
p2081[2] = r0722.10
p2081[4] = r0722.12
p2081[1] = r0722.9
p2081[9] = r0722.1
p2081[11] = r0722.3
p2081[13] = r0722.5
p2081[14] = r0722.6
p2081[15] = r0722.7
p2081[10] = r0722.2
p2081[12] = r0722.4
<2>
<2>
<2>
<2>
<2>
<2>
<2>
<2>
<2> Can be set via p0728 as input (DI) or output (DO).<1> Used in telegrams 390 to 396.
<1>
Refer to [1020.7]
PROFIdrive sampling time
<4> Only for CU320-2.
<4>
<4>
<4>
<4>