3 Function diagrams
3.10 Safety Integrated Extended Functions
SINAMICS G130/G150
1142 List Manual (LH2), 04/2014, A5E03263479A
Fig. 3-99 2853 – TM54F (F-DO 0 ... F-DO 3, DI 20 ... DI 23)
- 2853 -
Function diagram
87654321
DO: TM54F_MA, TM54F_SL
SINAMICS
19.09.13 V04.07.00
SI Extended Functions - TM54F (F-DO 0 ... F-DO 3, DI 20 ... DI 23)
fp_2853_51_eng.vsd
r10015 (12.00 ms)
X524.M
X524.+
24 V DC to the next device
+24 V electronic
M
M
P24
M
+
X524.+
DI: Digital Input
F-DO: Failsafe Digital Output
Example of a circuit with contactors - only
the feedback signal contacts are shown
X524.M
<1> Only for drive objekt TM54F_SL (Slave).
X514.M
X514.+
P24_1
M1
+
X514.+
X514.M
M1
M1
+24 V
DO 3+X535.2
X535.3
DO 3-
+24 V_1
F-DO 3
DI 23
M1
M1
DO 2+X533.2
X533.1
X533.3
DO 2-
F-DO 2
DI 22
X535.1
+24 V_1
M1
M1
M1
X532.10
DO 1+
DO 1-
+24 V_1
F-DO 1
DI 21
M1
M1
X520.1
L3+
DO 0+
DO 0-
F-DO 0
DI 20
+24 V_1
M1
M1
X525.2
X525.1
X523.2
X523.1
X523.3
X525.3
[2848.2]
[2857.8]
r10052.0
r10052.1
r10052.2
r10052.3
r10053.3
r10053.2
r10053.1
r10053.0
[2848.2]
[2848.2]
[2848.2]
[2857.8]
[2857.8]
[2857.8]
Read-back F-DO 1
Read-back F-DO 0
Read-back F-DO 2
Read-back F-DO 3
M
M
M
M
<1>
<1>
<1>
<1>
F-DO 3
r10052.3
[2857.8]
M
SL
F-DO 2
[2857.8]
M
r10052.2
MA
SL
F-DO 1
r10052.1
[2857.8]
M
MA
SL
F-DO 0
[2848.2]
[2857.8]
r10052.0
M
MA
SL