Fig. 3-164 8070 – Faults/alarms trigger word (r2129)
- 8070 -
Function diagram
87654321
DO: All objects
SINAMICS
05.11.13 V04.07.00
Diagnostics - Faults/alarms trigger word (r2129)
0. Fault code/alarm code
1. Fault code/alarm code
15. Fault code/alarm code
[0]
[1]
[15]
r2129
r2129.15
r2129.1
r2129.0
F/A trigger word
(e.g. as trigger condition to record traces)
0. Message/signal present
1. Message/signal present
15. Message/signal present
F/A trigger sel
p2128
Setting fault trigger/alarm trigger
Background