19-24
Cisco ONS 15454 Procedure Guide, R5.0
September 2005
Chapter 19 DLPs A200 to A299
DLP-A242 Create a BLSR on a Single Node
• Ring Type—Enter the ring type (either 2 Fiber or 4 Fiber) of the BLSR.
• Ring Name—Enter the BLSR ring name. If the node is being added to a BLSR, use the BLSR ring
name.
• Node ID—Enter the node ID. If the node is being added to a BLSR, use an ID that is not used by
other BLSR nodes.
• Ring Reversion—Enter the ring reversion time of the existing BLSR.
• West Line—Enter the slot on the node that will connect to the existing BLSR via the node’s west
line (port).
• East Line—Enter the slot on the node that will connect to the existing BLSR via the node’s east line
(port).
If you are adding the node to a four-fiber BLSR, complete the following for the second set of fibers:
• Span Reversion—Enter the span reversion time of the existing BLSR.
• West Line—Enter the slot on the node that will connect to the existing BLSR via the node’s west
line.
• East Line—Enter the slot on the node that will connect to the existing BLSR via the node’s east line.
Step 4 Click OK.
Note The BLSR is incomplete and alarms are present until the node is connected to other BLSR nodes.
Step 5 Return to your originating procedure (NTP).