Object 20B8h: Reset of changed input information
This object is used in PDOs to reset the state change information for the digital inputs shown in the Bits 24 to 30
in the object 60FD. Bit 0 to 6 are used to reset the information of the digital input 1 to 7.
Index 20B8h
Name Reset of changed input information
Object code VAR
Data type UNSIGNED16
Category optional
Access rw
PDO mapping possible
Value range UNSIGNED16
Default value 0
77 Kollmorgen | December 2010

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing