3 Function diagrams
3.5 PROFIdrive
SINAMICS G130/G150
1090 List Manual (LH2), 04/2014, A5E03263479A
Fig. 3-52 2496 – CU_ZSW1 status word 1, Control Unit interconnection
- 2496 -
Function diagram
87654321
fp_2496_54_eng.vsd
DO: CU_G, CU_S
S120/S150/G130/G150
27.06.13 V04.07.00
PROFIdrive - CU_ZSW1 status word 1 Control Unit interconnection
Signal sources for CU_ZSW1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
p2081[7] = r2139.7
p2081[8] = r0899.8
Implicitly
interconnected
-
Reserved
1 = Alarm present
1 = System time synchronized (SYNC)
1 = No fault present
Slave sign-of-life bit 0
Reserved
Reserved
1 = Fault present
Reserved
Reserved
1 = No alarm present
1 = No safety message present
Slave sign-of-life bit 1
Slave sign-of-life bit 2
Slave sign-of-life bit 3
CU_ZSW1.1
CU_ZSW1.2
CU_ZSW1.3
CU_ZSW1.4
CU_ZSW1.5
CU_ZSW1.6
CU_ZSW1.8
CU_ZSW1.9
CU_ZSW1.11
CU_ZSW1.12
CU_ZSW1.13
CU_ZSW1.14
CU_ZSW1.15
CU_ZSW1.7
CU_ZSW1.10
---ReservedCU_ZSW1.0
Inverted
[Function diagram]
signal source
[Function diagram]
Internal status word
Interconnection
parameters
MeaningSignal
-
- -
-
p2081[3] = r2139.3
<1> Used in telegrams 390 to 394.
<1>
PROFIdrive sampling time
-
-
-
-
-
-
p2081[11] = r3114.11
p2081[10] = r3114.10
p2081[9] = r3114.9
- -
<2> The ZSW1 is generated using the binector-connector converter (BI: p2080[0...15], inversion: p2088[0].0...p2088[0].15)
<2>