AKD User Guide | AIN Parameters
AIN.ISCALE
General Information
Type NV Parameter
Description Sets the analog current scale factor.
Units A/V
Range 0.001 to 22.4 A/V
Default Value 0.001 A/V
Data Type Float
See Also Analog Input Block Diagram
Start Version M_01-01-01-000
Fieldbus Index/Subindex Object Start Version
Modbus 4 M_01-03-00-000
Description
AIN.ISCALE sets the analog current scale factor that scales the analog input (AIN.VALUE) for DRV.OPMODE
= 1 (analog torque mode).
The value entered is the motor current per 10 V of analog input. This value may be either higher or lower than
100%, but the actual analog input will be limited by the application current limit (IL.LIMITN and IL.LIMITP).
Related Topics
10.4 Analog Input
Velocity Controller Environment Block Diagram (for the drive controller environment).