2-509MACHINE OPERATIONS OPERACIONES DE MECANIZADO
5. Third value mode indication lamp
Lit when the third value mode is selected. The
third value mode allows setting of the value for
turning the third value count up indication lamp
red.
6. Battery abnormality lamp
Lit when the voltage of the memory protection
battery drops.
7. Counter No. Indicator
Displays the counter number for the values
displayed on the present value indicator and the
setting value indicator.
8. Present value indicator
Displays the present value of the counter shown
on the counter number indicator.
9. Preset value indicator
Displays the first, second or third preset value of
the counter displayed on the counter number
indication.
5. Testigo indicador de modo del tercer valor
Se enciende cuando se selecciona el modo de tercer
valor. El modo de tercer valor permitirá ajustar el valor
para encender en rojo el testigo indicador de fin del
recuento del tercer valor.
6. Testigo de anomalía en la batería
Se enciende cuando se produce una caída del voltaje
de la batería de protección de memoria.
7. Indicador del N° del contador
Muestra el número de contador para los valores
mostrados en el indicador de valor actual y el indicador
de valor de ajuste.
8. Indicador del valor actual
Muestra el valor actual del contador mostrado en el
indicador del número de contador.
9. Indicador de valor por defecto
Muestra el primer, segundo o tercer valor preajustado
del contador mostrado en la indicación de número del
contador.
27-3-1-2 Setting the Second Preset Value
Ajuste del segundo valor de preajuste
When no mode lamps are lit, the counter
is in the operation mode.
If the lamp is lit, it is necessary to replace
the battery as soon as possible. To
replace the battery, contact the Mori
Seiki Service Department.
NOT A
Cuando no se enciende ningún testigo de modo,
el contador se encuentra en modo de
funcionamiento.
NOT A
Si se enciende el testigo, es necesario
reemplace la batería lo antes posible. Para
reemplazar la materia, contacte el departamento
de servicio Mori Seiki.
Procedure Procedimiento
Key
Tecla
Display
Visualización
1 Select the second value mode
Seleccione el modo de segundo
valor
is lit
está
encendido
2 Select the counter to be set
Seleccione el contador que se ajus-
tará
3 Select the digit to be set Seleccione el dígito que se ajustará
4 Input a preset value Introduzca un valor de preajuste
5
Set the second preset value
[The preset value blinks]
Ajuste el segundo valor de preajuste
[El valor de preajuste parpadea]
1. Each time the counter number select
key is pressed, the counter number
increases by one.
2. Each time the shift key is pressed, the
selected digit is shifted from the left to
right.
3. Each time the value progression key is
pressed, the value is increased by one.
NOT A
1. Cada vez que se pulsa la tecla de selección
del número del contador, se incrementa en uno el
número del contador.
2. Cada vez que se pulse la tecla de desplaza-
miento , el dígito seleccionado se desplazará
de izquierda a derecha.
3. Cada vez que se pulse la tecla de progresión del
valor , el valor aumentará en uno.