6-14
Cisco ONS 15454 Procedure Guide, R5.0
August 2005
Chapter 6 Create Circuits and VT Tunnels
NTP-A183 Create a Unidirectional DS-1 Circuit with Multiple Drops
Step 19 If you entered more than 1 in the Number of Circuits field, the Circuit Creation dialog box appears so
you can create the remaining circuits. Repeat Steps 5 through 18 for each additional circuit.
Step 20 When all the circuits are created, the main Circuits window appears. Verify that the circuits you created
are correct.
Step 21 Complete the “NTP-A135 Test Electrical Circuits” procedure on page 6-36. Skip this step if you built a
test circuit.
Stop. You have completed this procedure.
NTP-A183 Create a Unidirectional DS-1 Circuit with Multiple
Drops
Step 1 Complete the “DLP-A60 Log into CTC” task on page 17-66 at the node where you will create the circuit.
If you are already logged in, continue with Step 2.
Step 2 If you want to assign a name to the circuit source and destination ports before you create the circuit,
complete the “DLP-A314 Assign a Name to a Port” task on page 20-8. If not, continue with Step 3.
Step 3 From the View menu, choose Go to Network View.
Step 4 Click the Circuits tab, then click Create.
Step 5 In the Circuit Creation dialog box, complete the following fields:
Circuit Type—Choose VT.
Number of Circuits—Leave the default unchanged (1).
Auto-ranged—Unavailable when the Number of Circuits field is 1.
Step 6 Click Next.
Step 7 Define the circuit attributes (Figure 6-3):
Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters
(including spaces). Circuit names should be 44 characters or less if you want the ability to create
monitor circuits. If you leave the field blank, CTC assigns a default name to the circuit.
Size—VT1.5 is the default. You cannot change it.
Bidirectional—Uncheck for this circuit.
Create cross-connects only (TL1-like)—Check this box if you want to create one or more
cross-connects to complete a signal path for TL1-generated circuits. Also, VT tunnels and
Ethergroup sources and destinations are unavailable.
Purpose This procedure creates a unidirectional DS-1 circuit with multiple drops
(destinations).
Tools/Equipment None
Prerequisite Procedures NTP-A127 Verify Network Turn Up, page 6-4
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Provisioning or higher

Table of Contents

Other manuals for Cisco ONS 15454 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ONS 15454 Series and is the answer not in the manual?

Cisco ONS 15454 Series Specifications

General IconGeneral
Supported InterfacesEthernet
ManagementCisco Transport Controller (CTC), TL1, SNMP
Power Supply-48 VDC or AC (depending on power supply module)
Operating Temperature0 to 50°C (32 to 122°F) - varies by module
Storage Temperature-40°C to 70°C (-40 to 158°F)
Relative Humidity5 to 95%, noncondensing
Supported ProtocolsSONET/SDH, Ethernet, OTN
Platform TypeMulti-service transport platform