Cisco ONS 15454 Procedure Guide, R5.0
August 2005
Chapter 6 Create Circuits and VT Tunnels
NTP-A135 Test Electrical Circuits
Step 18 Verify that the VAP you just created appears in the circuits list. VAPs are identified in the Type column.
The VAP tunnel automatically transitions into the IS-NR service state.
Stop. You have completed this procedure.
NTP-A135 Test Electrical Circuits
Step 1 Complete the “DLP-A60 Log into CTC” task on page 17-66 at the node where you want to test the
electrical circuits. If you are already logged in, continue with Step 2.
Step 2 From the View menu, choose Go to Network View.
Step 3 Click the Circuits tab.
Step 4 Complete the “DLP-A230 Change a Circuit Service State” task on page 19-19 to set the circuit and
circuit ports to the maintenance service state (OOS-MA,MT). Take note of the original state because you
will return the circuit to that state later.
Step 5 Set the source and destination DS1 or DS3 card line length:
a. In network view, double-click the source node.
b. Double-click the circuit source card and click the Provisioning > Line tabs.
c. From the circuit source port Line Length drop-down list, choose the line length for the distance (in
feet) between the DSX (if used) or circuit termination point and the source ONS 15454.
d. Click Apply.
Purpose This procedures tests DS-1 and DS-3 circuits.
Tools/Equipment A test set and all appropriate cables
Prerequisite Procedures This procedure assumes you completed a facility loopback tests on the
fibers and cables from the source and destination ONS 15454s to the digital
signal cross-connect (DSX), and that you created a circuit using one of the
following procedures:
NTP-A139 Create a Half Circuit on a BLSR or 1+1 Node, page 6-52
NTP-A140 Create a Half Circuit on a Path Protection Node, page 6-54
NTP-A181 Create an Automatically Routed DS-1 Circuit, page 6-6
NTP-A182 Create a Manually Routed DS-1 Circuit, page 6-11
NTP-A183 Create a Unidirectional DS-1 Circuit with Multiple Drops,
page 6-14
NTP-A184 Create an Automatically Routed DS-3 Circuit, page 6-18
NTP-A185 Create a Manually Routed DS-3 Circuit, page 6-23
NTP-A186 Create a Unidirectional DS-3 Circuit with Multiple Drops,
page 6-25
Required/As Needed Required
Onsite/Remote Onsite
Security Level Provisioning or higher

Table of Contents

Other manuals for Cisco ONS 15454 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ONS 15454 Series and is the answer not in the manual?

Cisco ONS 15454 Series Specifications

General IconGeneral
Supported InterfacesEthernet
ManagementCisco Transport Controller (CTC), TL1, SNMP
Power Supply-48 VDC or AC (depending on power supply module)
Operating Temperature0 to 50°C (32 to 122°F) - varies by module
Storage Temperature-40°C to 70°C (-40 to 158°F)
Relative Humidity5 to 95%, noncondensing
Supported ProtocolsSONET/SDH, Ethernet, OTN
Platform TypeMulti-service transport platform

Related product manuals