EasyManua.ls Logo

Inter-Tel AXXESS - Page 1187

Inter-Tel AXXESS
1626 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 6-337
Programming
INTER-TEL
®
AXXESS
®
MANUAL VERSION 11.0 – May 2008
System Timers and Limits
PROGRAMMING
6
System Forward Initiate 15 2-255 seconds Determines how long a call will ring (unanswered) at
the principal station before advancing to the first for-
warding point in a system forwarding path.
Transfer – Attendant 30 10-255 seconds When an attendant transfers a call, this timer limits
the time a transferred call rings unanswered before it
recalls the attendant.
Transfer – Available 20 10-255 seconds Limits time a transferred call rings unanswered
before it recalls the transferring station. (Does not
apply to calls transferred by attendant stations or the
Voice Processor or calls transferred to a busy sta-
tion.)
Transfer – Busy 24 10-255 seconds Limits time a transferred call waits at a busy station
before recalling the transferring station. (Does not
apply to calls transferred by attendant stations or
Voice Processor or to calls transferred to an idle sta-
tion.)
Transfer – Voice Proces-
sor
20 10-255 seconds Limits time a transferred call waits at a Voice Proces-
sor destination before recalling the programmed
recall destination.
Trunk Busy Out 180 1-65535 seconds When a trunk is made busy using the administrator
DB Programming option (see page 5-289), this timer
starts. When it expires (or the administrator cancels
the busyout), the trunk is again made available.
Trunk Key Debounce 3 1-30 seconds The length of time the system will ignore subsequent
attempts to press a trunk button once it has been
pressed. This prevents a phone user from acciden-
tally disconnecting a call by re-selecting the trunk but-
ton if the button is pressed twice while answering a
call.
NOTE: The database contains a CO/IC Reseize sta-
tion flag that can be set to prevent users from reseiz-
ing a trunk. If selected, the station user cannot reseize
a trunk until it is disconnected by replacing the hand-
set, pressing the SPKR button, or pressing another
trunk button.
UCD Station Monitor Indi-
cation Frequency
15 1-255 seconds This is the length of the pause between hunt group
station monitoring tones.
Unsupervised CO 5 1-255 minutes Limits duration of outside calls transferred or for-
warded to outside telephone numbers before recall-
ing the primary attendant.
Valid Call 15 1-60 seconds Minimum duration of an outgoing call before it is
recorded in SMDR. Calls placed on hold or trans-
ferred are not subject to this timer.
Table 6-38: System Timers (Continued)
Timer
Default
Value
Range Purpose

Table of Contents

Other manuals for Inter-Tel AXXESS

Related product manuals