Page 5-316
System Features
INTER-TEL
®
AXXESS
®
MANUAL VERSION 11.0May 2008
Power Failure Capabilities
NOTE: Because the Message Print queue stores only 300 KB of information, only one Mes-
sage Print .log file is saved. This file is always assigned “1” as the <BlockNumber>.
53.31 For example, the filename N1_Apr14_0845_0850_1.cph represents the first file
in the history queue for Node 1. This file includes freeze information for April 14 between the
hours of 8:45AM and 8:50AM. Subsequent files for this history queue would be
N1_Apr14_0850_0900_2.cph, N1_Apr14_0900_0910_3.cph, etc.
53.32 Because the blocks are based on a limited amount of memory (i.e., 500K), the time
intervals for each file may not be the same. For example, if the system is extremely busy, two
files may reflect the same time interval. If this occurs, the only difference between the file
names would be the <BlockNumber> (e.g., N1_Apr14_0950_0950_1.cph and
N1_Apr14_0950_0950_2.cph).
53.33 Also, if the time changes (e.g., for daylight savings time) during a system freeze, one
block may appear to have the start and stop times reversed. For example, you may see
N1_Apr14_0100_0010_2.cph followed by N1_Apr214_0010_0020_3.cph. This
shows that the time changed at 1:00AM and that the second block of information was record-
ing during this time. For information about freezing the system, see page 6-52.
D. POWER FAILURE CAPABILITIES
53.34 The Call Processing Card (CPC) and Central Processor (CPU) card contain relay con-
tacts that can be used for power failure transfer which allows one or more single-line sets to
select predetermined trunks in the event of a processor board failure or a power failure. Addi-
tional equipment is required. See SPECIFICATIONS, page 2-103, for more information.
E. CUSTOMIZED SYSTEM PROGRAMMING REPORTS
53.35 Customized system programming reports can be created through the database (see
pages 6-82 and 6-339 in PROGRAMMING). The programmer can select the programming
area to be reported and then select the information that will be included. When extension num-
bers are listed in a report, they can be sorted by name, extension number, or circuit number.
Reports can also be titled.

Table of Contents

Other manuals for Inter-Tel AXXESS

Related product manuals