Page 3-63
Installation
INTER-TEL
®
AXXESS
®
MANUAL VERSION 11.0 – May 2008
SLC Block Cable Terminations (Europe)
INSTALLATION
3
Table 3-10. DKSC-16+ Cable Terminations on the MDF Blocks (Europe)
Twin Block Cables for use with DKSC-16 + Cabinet
7.46 For longer station loop lengths (up to 154 ohms/3,000 ft.), an optional power supply can
be connected to the DKSC-16 termination block. It must be a 36V DC power supply capable of
providing 120 mA per phone (1.92A for all 16 circuits). This option is only available on
DKSC-16s that are at revision level 2 or later or that have been modified and labeled with
FSM100995. The strap on jumper JP1 on the DKSC-16 Card must be placed over pins 1 and 2
to enable the external power supply.
Cable Pair Color Plug Pin No. Block No. Block Pair Circuit
1
White/Blue
Blue/White
1
26
1
1 01.01
2
White/Orange
Orange/White
2
27
2 02.01
3
White/Green
Green/White
3
28
3 03.01
4
White/Brown
Brown/White
4
29
4 04.01
5
White/Gray
Gray/White
5
30
5 05.01
6
Red/Blue
Blue/Red
6
31
6 06.01
7
Red/Orange
Orange/Red
7
32
7 07.01
8
Red/Green
Green/Red
8
33
8 08.01
9
Red/Brown
Brown/Red
9
34
9 09.01
10
Red/Gray
Gray/Red
10
35
10 10.01
11
Black/Blue
Blue/Black
11
36
2
111.01
12
Black/Orange
Orange/Black
12
37
2 12.01
13
Black/Green
Green/Black
13
38
3 13.01
14
Black/Brown
Brown/Black
14
39
4 14.01
15
Black/Gray
Gray/Black
15
40
5 15.01
16
Yellow/Blue
Blue/Yellow
16
41
6 16.01
17
Yellow/Orange
Orange/Yellow
17
42
7 Not used
18
Yellow/Green
Green/Yellow
18
43
8 Not used
19
Yellow/Brown
Brown/Yellow
24
25
9
Not used
GND
20
Yellow/Gray
Gray/Yellow
49
50
10
Not used
+36V DC