Page 3-35
Installation
INTER-TEL
®
AXXESS
®
MANUAL VERSION 11.0 May 2008
PRI Trunk Terminations from RJ45 Jacks
INSTALLATION
3
Figure 3-16. PRI Trunk Terminations from RJ45 Jacks
Figure 3-17. Line Jack Unit Assembly Wiring for PRI Trunks
FOUR-PAIR,
NON-REVERSING
MOD-TO-MOD
LINE CORD
FOUR-PAIR,
NON-REVERSING,
MOD-TO-MOD
LINE CORD
E1 CABLE
EIGHT-CONDUCTOR
LINE JACK UNIT ASSEMBLIES
RJ45
JACK
TO
NETWORK
TO
E1/PRI
PROVIDER
CARD
FOUR-PAIR,
NON-REVERSING,
MOD-TO-MOD
LINE CORD
E1/PRI CARD
RJ45 JACK
1
2
3
4
5
6
7
8
R1
T1
R
T
1
3
5
7
2
4
6
8
NOTE: OUT = transmit to network, IN = receive from network.