Page 5-306
System Features
INTER-TEL
®
AXXESS
®
MANUAL VERSION 11.0May 2008
Call Cost Accounting
53.3 For European Systems: The multiplicative factor adjusts the peak per-minute call cost
for standard and cheap rates of outgoing calls. For example, the call cost multiplier is 0.65 if
calls are 35% less expensive after 6:00PM. The peak (P), standard (S), and cheap (C) multipli-
cative factors are used on the following schedule:
53.4 The following two programmable factors are based on the non-programmable Daytime
(Peak) factor of 1.00. The system is always in the Peak time period, using the Daytime (Peak)
multiplicative factor of 1.00, unless the system falls into an Evening (Standard) or Night/
Weekend (Cheap) time period at which time it follows the corresponding designated factor:
NOTE: Multiplicative Factor is applied to a non-programmable Peak rate of 1.00. Because the
Peak rate is non-programmable, it does not appear in the Call Cost screen/window under Multi-
plicative Factors in DB Programming.
53.5 If call cost is set to zero, call cost will not display during the call, and the SMDR print-
out will show 00.00.
53.6 In a network setting, the call cost shown on the display and SMDR output use the fac-
tors and rates for the node on which the trunk resides. In other words, if a station on Node 1
dials what is considered a long-distance number on Node 1, but the call is routed to Node 2
where the number is considered local, the phone will use the local call cost rate from Node 2.
The call rate used for calls between nodes will be based on the Network call rate. (See page 6-
268 for programming information.)
53.7 All outgoing calls using a trunk that is not subject to toll restriction are classified as one
of the following call types for call cost calculation (call cost type is programmed in the data-
base).
Table 5-44. Multiplicative Factors (Europe)
SUN MON TUE WED THU FRI SAT
9 AM to
1 PM
CPPPPPC
1 PM to
6 PM
CSSSSSC
6 PM to
9 AM
CCCCCCC
Table 5-45. Programmable Factors
Description Multiplicative Factor
Daytime (Peak) 1.00 (See Note below)
Evening (Standard) 1.00
Night/Weekend
(Cheap)
1.00