EasyManua.ls Logo

Inter-Tel AXXESS - Page 1372

Inter-Tel AXXESS
1626 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 7-92
Troubleshooting
INTER-TEL
®
AXXESS
®
MANUAL VERSION 11.0 May 2008
Factory Default Procedure
CPLD-generated TA (DTACK) not detected, using 7 wait states for SRAM.
SRAM detected: width 16 bits, size 4194304 bytes.
Testing RAM ... successful!
Decompressing card-specific code to RAM ... successful!
(decompressing 2800668 bytes into 8773820 bytes)
Default-CPC procedure requested, please press the * button again to
confirm …
- - - - - - - - - - - -
8.40 All the LEDs light solid for 3 seconds. If the * button is not pressed again at this time it
will not default the board.
8.41 If the * button is not pressed the following message appears: “No confirmation
received, skipping default-CPC procedure ...”
8.42 If the * button is pressed, the CPU will continue with the default procedure, and the fol-
lowing message appears: “
Initiating default-CPC procedure; do not power
down the system!
- - - - - - - - - -
Resetting OS database ...
Programming the Ethernet address into the flash device ...
Erasing parameter block 2 ...
Programming parameter block 2 ...
Erasing parameter block 1 ...
Programming parameter block 1 ...
Ethernet address successfully programmed.
OS database reset.
Deleting SRAM (4194304 bytes) ... successful!
Erasing file-system sector ... successful!
Default-CPC procedure completed!
Resetting ...
n