Page 6-334
Programming
INTER-TEL
®
AXXESS
®
MANUAL VERSION 11.0 – May 2008
System Timers and Limits
Interdigit – Long
Interdigit – Short
15
4
2-255 seconds
2-30 seconds
Used in determining end of dialing. Short timer is
used after a valid number has been dialed. Long
timer is used until digits form a valid number.
Loopback Timeout 600 10-10000 seconds This is the maximum allowed length of a remote loop-
back test. If the timer expires, the test is automati-
cally terminated.
LS Dialing Wait After
Connect
15 1-50 tenths
(0.1-5.0 sec.)
The length of time the system waits for outside dial
tone before dialing or checking the trunk for a discon-
nect.
LS/GS Caller ID Relay
Hold
3747 2-4000 millisec.
(0.002-4.0 sec.)
Amount of time the system will look for Caller ID
[CLIP] information when a call is received.
LS/GS Caller ID Ring Idle 128 2-4000 millisec.
(0.002-4.0 sec.)
This sets the time between the end of first ring and
the time at which the system begins to check for
Caller ID [CLIP] information.
NOTE: The Caller ID [CLIP] timer values combined
must be shorter than the period of silence between
CO rings.
LS/GS CO Hookflash 60 2-1000 hun-
dredths
(0.02-10.0 sec.)
Adjusts the duration of the timed hookflash (recall)
that is sent over the trunk by the system when the
Hookflash feature code is used.
LS/GS CO-CO Discon-
nect
35 2-1000 hun-
dredths
(0.02-10.0 sec.)
A call is disconnected by the system if it detects loss
of loop current lasting longer than this timer during
trunk-to-trunk calls.
LS/GS Dialing Disconnect 120 2-1000 hun-
dredths
(0.02-10.0 sec.)
The connection is dropped if the system detects loss
of loop current lasting longer than this timer during
dialing.
LS/GS Dialing Wait After
Hookflash
30 2-199 tenths
(0.2-19.9 sec.)
Delays dialing after a hookflash (recall) to allow the
system and central office hardware to recover.
LS/GS IC-CO Disconnect 60 2-1000 hun-
dredths
(0.02-10.0 sec.)
A call is disconnected by the system if it detects loss
of loop current (lasting longer than this timer) during
station-to-trunk calls.
LS/GS Inter-Ring Silence 60 1-250 tenths
(0.1-25.0 sec.)
Indicates the duration of the silence between rings on
an incoming call to determine if the trunk has stopped
ringing prior to being seized. In most areas, trunk ring
pattern is 2 seconds on/ 4 seconds off. Check with
the local telephone company for the ring pattern in
your area.
NOTE: This timer must always be set higher than
the central office's ring off time.
Table 6-38: System Timers (Continued)
Timer
Default
Value
Range Purpose