Page 1-10
Overview
INTER-TEL
®
AXXESS
®
MANUAL VERSION 11.0 – May 2008
System Feature Capacities
Programmable reminder messages
Message requests per system
20
256
20
512
20
1024
20
1792
Do-not-disturb messages
Messages per system
20
256
20
512
20
1024
20
1792
System forwarding paths
Paths per station
Points per path
200
3
4
200
3
4
200
3
4
200
3
4
ARS
Route groups
Facility Groups per route group
Trunk groups per facility group
Dial rules (16 digits each)
- total
- programmable
Callback requests per system
Camp on requests per system
50
100
104
32
26
256
f
256
f
50
100
208
32
26
512
f
512
f
100
100
208
32
26
1024
f
1024
f
100
100
208
32
26
1792
f
1792
f
Toll restriction user groups (U.S. only)
Area code tables per user group
Area codes per table
Ext. area codes per user group
Office code tables per ext. area code
Office codes per table
8
1
800
6
1
800
8
1
800
6
1
800
8
1
800
6
1
800
8
1
800
6
1
800
Station class of service designations 16 16 16 16
Absorbed digit patterns per system
Digits per pattern
50
48
50
48
50
48
50
48
Account codes
Forced
Standard
Digits per code
256
256
3-12
512
512
3-12
5000
5000
3-12
5000
5000
3-12
Hunt groups
Per system
Stations per hunt group
Announce stations per hunt group
Overflow stations per hunt group
Recall destinations per hunt group
Agent IDs per ACD hunt group
Stations in an all-ring hunt group
75
2500
g
1
1
1
1000
30
75
5000
g
1
1
1
1000
60
300
5000
g
1
1
1
3000
60
300
5000
g
1
1
1
3000
60
Keymap group assignments
Keyset
DSS/BLF
User-programmable buttons per phone
25
20
35
25
20
35
250
20
35
250
20
35
Extension lists per system
Station or trunk numbers per list
Stations per list used for hunt groups
Stations per list used for paging
256
d
224
30
60
512
d
448
30
60
1024
d
20,000
60
120
1792
d
20,000
60
120
Busy Hour Call Completion (BHCC)
h
23,000
i
23,000
i
33,500
j
33,500
j
a. The 512CPS capacities also apply to quad-chassis systems running system version 7.0 or ear-
lier.
b. ForeRunner LE
®
155 Asynchronous Transfer Mode (ATM) switch was recently replaced by the
Ericsson
®
(Marconi) ASX™ 200BX ATM switch. The new switch provides the same function-
ality as the ForeRunner LE155 switch and includes an Ethernet port for remote access. For de-
tails, see the ATM Switch Installation Instructions
.
c. If Music-On-Hold (MOH) is used in a cabinet, one slot (per cabinet) is subtracted from available
time slots. This one slot is dedicated for MOH and held up until the system is reset. MOH is
altered each time the system is reset.
d. The maximum number of stations and trunks that can be installed is limited by the number of
circuit cards installed and voice channels and/or system memory resources available. For sys-
tems using more than 112 ports, use the faster CPC or CP Server.
Table 1-2. System Feature Capacities (Continued)
Feature
Capacity
256
Capacity
CPS512
a
Capacity
CPS1024
Capacity
ATM
b