Page 5-280
System Features
INTER-TEL
®
AXXESS
®
MANUAL VERSION 11.0May 2008
Station Programming Using an Administrator's Station
c. Toll Restriction: Allows you to set the station class of service for day and/or night
modes. To select it, press or the
TOLL RESTRICTION menu button. Then do
the following:
1.) The display shows TOLL RESTRICTION OPTION. Press or the COS
DAY menu button to program day mode toll restriction. Or, press or the
COS NIGHT menu button to program night mode toll restriction.
The display shows SET DAY (or NIGHT) COS XX. If this is not the COS
you want to program, scroll to the correct COS by pressing the high end of
the Volume button or
NEXT menu button to scroll forward, or press the low
end of the Volume button or
PREVIOUS menu button to scroll backward.
The default COS numbers are as follows. See page 5-103 for definitions.
For U.S. Systems:
COS 01 – ARS Only
COS 02 – Deny Area/Office
COS 03 – Deny Operator
COS 04 – Deny Toll Access
COS 05 – Deny International
COS 06 – Deny Equal Access
COS 07 – Deny Local Calls
COS 08 – Denied Numbers
COS 09 – Allowed Numbers
For European Systems:
COS 01 – ARS Only
COS 02 – Deny Operator
COS 03 – Deny Toll Access
COS 04 – Deny International
COS 05 – Deny Local Calls
COS 06 – Denied Numbers
COS 07 – Allowed Numbers
NOTE: Numbers listed in the “Emergency Number” table are never
restricted, no matter how the COS shown above is programmed.
2.)
When the correct COS is displayed, press or the ON menu button to
enable the toll restriction. Or, press or the
OFF menu button to disable it.
3.) If desired, repeat steps c2 and c3 to program additional COS toll restrictions.
4.) Press or ACCEPT to save the COS programming. The display shows
DATABASE UPDATED and then returns to the TOLL RESTRICTION
OPTION prompt.
5.) Press again to exit to the ENTER STATION OPTION prompt.
6. When the display shows ENTER STATION OPTION, press again to exit to the
ENTER STATION EXTENSION prompt. You can then program another station by
repeating these steps or press or
ACCEPT once more to exit to the ENTER DATA-
BASE OPTION prompt.
7. When finished with all programming, press while the ENTER DATABASE
OPTION prompt is displayed. This ends the programming session.