50-66
Cisco MDS 9000 Family Fabric Manager Configuration Guide
OL-17256-03, Cisco MDS NX-OS Release 4.x
Chapter 50 Configuring iSCSI
iSCSI Authentication Setup Guidelines and Scenarios
d. Set the Zone Name field to iscsi-zone-2 and click OK.
e. Select the iscsi-zone-2 folder in the left navigation pane and click Insert.
f. Set the ZoneBy radio button toWWN.
g. Set the Port WWN to the pWWN for one of the Fibre Channel targets (for example,
21:00:00:20:37:6f:fe:5). and click Add.
h. Set the Port WWN to the pWWN for another of the Fibre Channel targets (for example,
21:00:00:20:37:a6:a6:5d). and click Add.
i. Set the ZoneBy radio button to iSCSI IP Address/Subnet.
j. Set the IP Address/Mask field to the IP Address for Host 2 iSCSI initiator (10.15.1.11) and click
Add.
Step 13 Create a zone set in VSAN 2 and activate it.
a. In Fabric Manager, choose Zones > Edit Local Full Zone Database.
b. Select VSAN 2 from the VSAN drop-down menu in the Edit Local Full Zone Database dialog box.
c. Select the Zoneset folder in the left navigation pane and click Insert.
d. Set the Zoneset Name to zonset-iscsi-2 and click OK.
e. Click on the zoneset-iscsi-2 folder and click Insert.
f. Set the Zone Name field to iscsi-zone-2 and click OK.
g. Click Activate to activate the new zone set.
h. Click Continue Activation to finish the activation.
Step 14 Start the iSCSI clients on both hosts
Step 15 Show all the iSCSI sessions.
a. In Device Manager, choose Interface > Monitor > Ethernet and select the iSCSI connections tab
to show all the iSCSI sessions.
b. In Device Manager, choose IP > iSCSI and select the Session Initiators tab.
c. Click Details.
Step 16 In Fabric Manager, choose End Devices > iSCSI in the Physical Attributes pane to verify the details of
the two iSCSI initiators.
Step 17 In Fabric Manager, choose Zones > Edit Local Full Zone Database to view the active zone set. The
iSCSI initiators' FC IDs are resolved.
Step 18 In Device Manager, choose FC > Name Server. The Fibre Channel name server shows the virtual N
ports created for the iSCSI hosts.
Step 19 In Device Manager, Choose FC > Name Server.
Step 20 Click the Advanced tab. Verify the detailed output of the iSCSI initiator nodes in the Fibre Channel
name server.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals