Page #1313 background image
CHAPTER
Send documentation comments to mdsfeedback-doc@cisco.com
63-1
Cisco MDS 9000 Family Fabric Manager Configuration Guide
OL-17256-03, Cisco MDS NX-OS Release 4.x
63
Configuring Fabric Configuration Servers
This chapter describes the Fabric Configuration Server (FCS) feature provided in the Cisco MDS 9000
Family of directors and switches. It includes the following sections:
• About FCS, page 63-1
• Displaying FCS Discovery, page 63-3
• Displaying FCS Elements, page 63-3
• Creating an FCS Platform, page 63-4
• Displaying FCS Fabric Ports, page 63-5
• Default Settings, page 63-6
About FCS
The Fabric Configuration Server (FCS) provides discovery of topology attributes and maintains a
repository of configuration information of fabric elements. A management application is usually
connected to the FCS on the switch through an N port. The FCS views the entire fabric based on the
following objects:
• Interconnect element (IE) object—Each switch in the fabric corresponds to an IE object. One or
more IE objects form a fabric.
• Port object—Each physical port in an IE corresponds to a port object. This includes the switch ports
(xE, Fx, and TL ports) and their attached Nx ports.
• Platform object—A set of nodes may be defined as a platform object to make it a single manageable
entity. These nodes are end-devices (host systems, storage subsystems) attached to the fabric.
Platform objects reside at the edge switches of the fabric.
Each object has its own set of attributes and values. A null value may also be defined for some attributes.
In the Cisco MDS 9000 Family switch environment, multiple VSANs constitute a fabric, where one
instance of the FCS is present per VSAN.
As of Cisco NX-OS Release 4.1(1), FCS supports the discovery of virtual devices. The fcs
virtual-device-add command, issued in FCS configuration submode, allows you to discover virtual
devices in a particular VSAN or in all VSANs. The devices that are zoned for IVR must be discovered
with this command and have request domain_ID (RDI) enabled, before activating the IVR zone set.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals