59-2
Cisco MDS 9000 Family Fabric Manager Configuration Guide
OL-17256-03, Cisco MDS NX-OS Release 4.x
Chapter 59 Configuring RMON
Configuring RMON Using Threshold Manager
• Value—The value of the variable that you want the alarm to trigger at. This value is the difference
(delta) between two consecutive polls of the variable by Device Manager.
• Sample—The sample period (in seconds) between two consecutive polls of the variable. Select your
sample period such that the variable does not cross the threshold value you set under normal
operating conditions.
• Warning—The warning level used by Device Manager to indicate the severity of the triggered alarm.
This is a Fabric Manager and Device Manager enhancement to RMON.
Note To configure any type of RMON alarm (absolute or delta, rising or falling threshold) click More on the
Threshold Manager dialog box. You should be familiar with how RMON defines these concepts before
configuring these advanced alarm types. Refer to the RMON-MIB (RFC 2819) for information on how
to configure RMON alarms.
Note You must also configure SNMP on the switch to access RMON MIB objects.
RMON Alarm Configuration
Threshold Manager provides a list of common MIB objects to set an RMON threshold and alarm on. You
can also set an alarm on any MIB object. The specified MIB must be an existing SNMP MIB object in
standard dot notation (1.3.6.1.2.1.2.2.1.14.16 for ifInOctets.16).
Use one of the following options to specify the interval to monitor the MIB variable (ranges from 1 to
4294967295 seconds):
• Use the delta option to test the change between samples of a MIB variable.
• Use the absolute option to test each MIB variable directly.
• Use the delta option to test any MIB objects that are counters.
The range for the rising threshold and falling threshold values is -2147483647 to 2147483647.
Caution The falling threshold must be less than the rising threshold.
You can optionally specify the following parameters:
• The event-number to trigger if the rising or falling threshold exceeds the specified limit.
• The owner of the alarm.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals