59-15
Cisco MDS 9000 Family Fabric Manager Configuration Guide
OL-17256-03, Cisco MDS NX-OS Release 4.x
Chapter 59 Configuring RMON
Create RMON Alarms in Fabric Manager
Figure 59-17 Create RMON Thresholds Events Dialog Box
Step 4 Configure the RMON threshold event attributes by choosing the type of event (log, snmptrap, or
logandtrap).
Step 5 Increment the index. If you try to create an event with the existing index, you see a duplicate entry error
message.
Step 6 (Optional) Provide a description and a community.
Step 7 Click Create, then close this dialog box.
Step 8 Verify that your event is listed in the remaining RMON Thresholds dialog box.
Step 9 Click Close to close the RMON Thresholds dialog box.
Managing RMON Alarms
To view the alarms that have already been enabled using Device Manager, follow these steps:
Step 1 Choose Admin > Events > Threshold Manager and click More in the Threshold Manager dialog box.
Step 2 Click the Alarms tab.
You see the RMON Thresholds dialog box as shown in Figure 59-18.
Figure 59-18 RMON Thresholds Dialog Box