32-7
Cisco MDS 9000 Family Fabric Manager Configuration Guide
OL-17256-03, Cisco MDS NX-OS Release 4.x
Chapter 32 Configuring Fibre Channel Routing Services and Protocols
FSPF Interface Configuration
Configuring FSPF Link Cost
To configure FSPF link cost using Fabric Manager, follow these steps:
Step 1 Expand Switches, expand Interfaces and then select FC Physical.
You see the interface configuration in the Information pane.
Step 2 Click the FSPF tab.
You see the FSPF interface configuration in the Information pane as shown in Figure 32-5.
Figure 32-5 Fibre Channel Physical FSPF Interface
Step 3 Double-click in the Cost field of a switch and change the value.
Step 4 Click Apply Changes to save these changes, or click Undo Changes to discard any unsaved changes.
About Hello Time Intervals
You can set the FSPF Hello time interval to specify the interval between the periodic hello messages sent
to verify the health of the link. The integer value can range from 1 to 65,535 seconds.
Note This value must be the same in the ports at both ends of the ISL.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals