62-33
Cisco MDS 9000 Family Fabric Manager Configuration Guide
OL-17256-03, Cisco MDS NX-OS Release 4.x
Chapter 62 Configuring Call Home
Message Contents
Severity levels range from 0 to 9, with 9 having the highest urgency. Each syslog level has keywords and
a corresponding syslog level as listed in
Table 62-4.
Note Call Home does not change the syslog message level in the message text. The syslog message texts in
the Call Home log appear as they are described in the Cisco MDS 9000 Family System Messages Guide.
Note Call Home severity levels are not the same as system message logging severity levels (see Chapter 61,
“Configuring System Message Logging” and the Cisco MDS 9000 Family System Messages Guide).
Message Contents
The following contact information can be configured on the switch:
Name of the contact person
Phone number of the contact person
E-mail address of the contact person
Mailing address to which replacement parts must be shipped, if required
Site ID of the network where the site is deployed
Contract ID to identify the service contract of the customer with the service provider
Table 62-5 describes the short text formatting option for all message types.
Ta b l e 62-4 Severity and Syslog Level Mapping
Call Home Level Keyword Used Syslog Level Description
Catastrophic (9) Catastrophic N/A Network wide catastrophic failure.
Disaster (8) Disaster N/A Significant network impact.
Fatal (7) Fatal Emergency (0) System is unusable.
Critical (6) Critical Alert (1) Critical conditions, immediate attention needed.
Major (5) Major Critical (2) Major conditions.
Minor (4) Minor Error (3) Minor conditions.
Warning (3) Warning Warning (4) Warning conditions.
Notify (2) Notification Notice (5) Basic notification and informational messages.
Possibly independently insignificant.
Normal (1) Normal Information (6) Normal event signifying return to normal state.
Debug (0) Debugging Debug (7) Debugging messages.
Ta b l e 62-5 Short Text Messages
Data Item Description
Device identification Configured device name
Date/time stamp Time stamp of the triggering event

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals