EasyManuals Logo

Cisco AP775A - Nexus Converged Network Switch 5010 User Manual

Cisco AP775A - Nexus Converged Network Switch 5010
1486 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #995 background imageLoading...
Page #995 background image
Send documentation comments to mdsfeedback-doc@cisco.com
46-11
Cisco MDS 9000 Family Fabric Manager Configuration Guide
OL-17256-03, Cisco MDS NX-OS Release 4.x
Chapter 46 Configuring Port Security
Activating Port Security
Step 3 Click in the Action column under Activation, next to the switch or VSAN on which you want to activate
port security and select the forceactivate option.
Step 4 Set the Action field you want for that switch.
Step 5 Click the CFS tab and set the command column to commit on all participating switches in the VSAN.
Step 6 Click Apply Changes in Fabric Manager or Apply in Device Manager to save these changes.
Database Reactivation
Tip If auto-learning is enabled, and you cannot activate the database, you will not be allowed to proceed. .
To reactivate the port security database using Fabric Manager, follow these steps:
Step 1 Disable auto-learning.
Step 2 Copy the active database to the configured database.
Tip If the active database is empty, you cannot perform this step.
Step 3 Make the required changes to the configuration database.
Step 4 Activate the database.
Copying an Active Database to the Config Database
To copy the active database to the config database using Fabric Manager, follow these steps:
Step 1 Expand a VSAN and select Port Security in the Logical Domains pane.
You see the port security configuration for that VSAN in the Information pane.
Step 2 Click the Actions tab.
You see the switches for that VSAN.
Step 3 Check the CopyActive ToConfig check box next to the switch for which you want to copy the database.
The active database is copied to the config database when the security setting is activated.
Step 4 Uncheck the CopyActive ToConfig check box if you do not want the database copied when the security
setting is activated.
Step 5 Click the CFS tab and set the command column to commit on all participating switches in the VSAN.
Step 6 Click Apply Changes to save these changes or click Undo Changes to discard any unsaved changes.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals