25-18
Cisco MDS 9000 Family Fabric Manager Configuration Guide
OL-17256-03, Cisco MDS NX-OS Release 4.x
Chapter 25 Configuring Domain Parameters
FC IDs
Ensure that the required VSAN is an active VSAN—persistent FC IDs can only be configured on
active VSANs.
Verify that the domain part of the FC ID is the same as the runtime domain ID in the required VSAN.
If the software detects a domain mismatch, the command is rejected.
Verify that the port field of the FC ID is 0 (zero) when configuring an area.
Note FICON uses a different scheme for allocating FC IDs based in the front panel port number. This scheme
takes precedence over FC ID persistence in FICON VSANs.
Configuring Persistent FC IDs