EasyManuals Logo

Cisco AP775A - Nexus Converged Network Switch 5010 User Manual

Cisco AP775A - Nexus Converged Network Switch 5010
1486 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #574 background imageLoading...
Page #574 background image
Send documentation comments to mdsfeedback-doc@cisco.com
25-18
Cisco MDS 9000 Family Fabric Manager Configuration Guide
OL-17256-03, Cisco MDS NX-OS Release 4.x
Chapter 25 Configuring Domain Parameters
FC IDs
• Ensure that the required VSAN is an active VSAN—persistent FC IDs can only be configured on
active VSANs.
• Verify that the domain part of the FC ID is the same as the runtime domain ID in the required VSAN.
If the software detects a domain mismatch, the command is rejected.
• Verify that the port field of the FC ID is 0 (zero) when configuring an area.
Note FICON uses a different scheme for allocating FC IDs based in the front panel port number. This scheme
takes precedence over FC ID persistence in FICON VSANs.
Configuring Persistent FC IDs

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals