Send documentation comments to mdsfeedback-doc@cisco.com
14-6
Cisco MDS 9000 Family Fabric Manager Configuration Guide
OL-17256-03, Cisco MDS NX-OS Release 4.x
Chapter 14 Configuring FlexAttach Virtual pWWN
Configuring FlexAttach Virtual pWWN
Figure 14-5 Virtual pWWN Tab View in Fabric Manager
Note The interface mentioned in the interface value must be in a shut state.
Mapping pWWN to Virtual pWWN
You can configure virtual pWWNs through real pWWNs. This process is required for NPIV hosts
containing multiple pWWNs, of which only FLOGI is mapped to the virtual pWWN. Subsequent
FDSIDs will have different mappings.
Several checks are done by the NPV core to ensure the uniqueness of virtual pWWNs in the switch across
the NPV switches. When duplicate virtual pWWNs are configured, the subsequent logins are rejected by
the NPV core switch.To map pWWN to virtual pWWN, follow these steps:
Step 1 In the FlexAttach window, select the Physical to Virtual WWNs tab.
You se e t he Physical to Virtual WWNs tab view as shown in Figure 14-6.