21-5
Cisco MDS 9000 Family Fabric Manager Configuration Guide
OL-17256-03, Cisco MDS NX-OS Release 4.x
Chapter 21 Configuring N Port Virtualization
About NPV
Default Port Numbers
Port numbers on NPV-enabled switches will vary depending on the switch model. For details about port
numbers for NPV-eligible switches, see Chapter 11, “On-Demand Port Activation Licensing.
NPV CFS Distribution over IP
NPV devices use only IP as the transport medium. CFS uses multicast forwarding for CFS distribution.
NPV devices do not have ISL connectivity and FC domain. To use CFS over IP, multicast forwarding has
to be enabled on the ethernet IP switches all along the network that physically connects the NPV switch.
You can also manually configure the static IP peers for CFS distribution over IP on NPV-enabled
switches. For more information, see the “Configuring Static IP Peers for CFS over IP” section on
page 7-17.
NPV Traffic Management
This sections discusses the following aspects of load balancing:
Auto, page 21-5
Traffic Map, page 21-5
Disruptive, page 21-6
Auto
Before Cisco MDS SAN-OS Release 3.3(1a), NPV supported automatic selection of external links.
When a server interface is brought up, an external interface with the minimum load is selected from the
available links. There is no manual selection on the server interfaces using the external links. Also, when
a new external interface was brought up, the existing load was not distributed automatically to the newly
available external interface. This newly brought up interface is used only by the server interfaces that
come up after this interface.
Traffic Map
As in Cisco MDS SAN-OS Release 3.3(1a) and NX-OS Release 4.1(1a), NPV supports traffic
management by allowing you to select and configure the external interfaces that the server uses to
connect to the core switches.
Note When the NPV traffic management is configured, the server uses only the configured external interfaces.
Any other available external interface will not be used.
The NPV traffic management feature provides the following benefits:
Facilitates traffic engineering by providing dedicated external interfaces for the servers connected
to NPV.
Uses the shortest path by selecting external interfaces per server interface.
Uses the persistent FC ID feature by providing the same traffic path after a link break, or reboot of
the NPV or core switch.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals