EasyManuals Logo

Cisco AP775A - Nexus Converged Network Switch 5010 User Manual

Cisco AP775A - Nexus Converged Network Switch 5010
1486 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #333 background imageLoading...
Page #333 background image
Send documentation comments to mdsfeedback-doc@cisco.com
14-11
Cisco MDS 9000 Family Fabric Manager Configuration Guide
OL-17256-03, Cisco MDS NX-OS Release 4.x
Chapter 14 Configuring FlexAttach Virtual pWWN
Using the Server Admin FlexAttach Wizards
Figure 14-10 Pre Configure Server - Basic Configuration
Step 3 In the Basic Configuration window, check the check box to select one or more switches from the list of
NPV switches in the fabric.
Step 4 Check the Enable FlexAttach Auto on every port check box to enable FlexAttach on all the ports of
all the selected switches.
Step 5 (Optional) From the VSAN ID drop-down list, select a VSAN ID to assign the selected VSAN ID to all
the ports.
Note Only the set of VSANs to which all the selected switches belong are listed. If no VSAN ID is
selected, then the existing VSAN configuration is retained.
Step 6 Click the Up or Down radio button to assign the selected interface status.
Note The status of only the F ports in the selected switches will be brought to up or down.
Step 7 Click Finish to pre-configure the selected settings to all the ports on all the selected switches.
The Configuration window is displayed with the finished message. (Figure 14-11)

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals