Figure 14-10 Pre Configure Server - Basic Configuration
Step 3 In the Basic Configuration window, check the check box to select one or more switches from the list of
NPV switches in the fabric.
Step 4 Check the Enable FlexAttach Auto on every port check box to enable FlexAttach on all the ports of
all the selected switches.
Step 5 (Optional) From the VSAN ID drop-down list, select a VSAN ID to assign the selected VSAN ID to all
the ports.
Note Only the set of VSANs to which all the selected switches belong are listed. If no VSAN ID is
selected, then the existing VSAN configuration is retained.
Step 6 Click the Up or Down radio button to assign the selected interface status.
Note The status of only the F ports in the selected switches will be brought to up or down.
Step 7 Click Finish to pre-configure the selected settings to all the ports on all the selected switches.
The Configuration window is displayed with the finished message. (Figure 14-11)